Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
I'm Online Chat Now

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System
Wall Mounted Fan Coil FCU For Data Centres Free Cooling System Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Large Image :  Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Product Details:

Place of Origin: China
Brand Name: Shenglin
Certification: /
Model Number: SL-ZKW Series

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: 500~4000USD/unit
Packaging Details: Plywood wooden box or pallet
Delivery Time: 35~40days
Payment Terms: T/T, Western Union
Supply Ability: 100 Units Per Month
Detailed Product Description
Supply Power: 220V / 50Hz. Compressor Type: No Compressor
Air Cooled Or Water Cooled: Fresh Air Cooled Feature: Has Free Cooling Valve
Mounting: Wall Mount Fant Type: EC Fan
High Light:

2000m3/H FCU AC Unit

,

2000m3/H Clean Room Air Conditioning System

,

FCU Clean Room Air Conditioning System

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

 

Features:

1. The maximum air flow of at least 2000 m3 / h.
2. Minimum airflow is not more than 700 m3 / h.
3. Power supply 36-56 VDC (direct current).
4. Power consumption at the maximum air flow isn’t more than 300 W.
5. Power consumption at a minimum flow of air isn’t more than 20 W.
6. The power of the electric heater at least 1.5 kW, voltage 220V / 50Hz.

 

Technical Data:

Structure:

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System 0

FCU should has:
1. Insulated body and the valve free cooling for inadmissibility through freezing at outdoor temperatures down to - 40 ° C by the cold climate zone, and up to - 20C in the performance for the warm climate zone;
2. Free cooling valve actuator with analog control, which allows smoothly change the position of the valve;
3. Air filter cassette-type, folding to replace the filter element, contamination control system;
4. Mosquito protection (pre-filter);
5. The prevention of access of outside air, controlled by a signal fire system;
6. Control system aerodynamic resistance cleaning filter (air flow pressure sensors at the inlet and outlet filters);
7. Electric heater, controlled by the controller (as an option).
8. FCU should has double filter which can protect BS from dust

 

Application:

Data centres or IT environments in colder climates.

 