D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin

Certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
I'm Online Chat Now

D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin

D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin
D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin

Large Image :  D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin

Product Details:

Place of Origin: China
Brand Name: Shenglin
Certification: CE and RoHs
Model Number: SHSL-D2 Series

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: 6000~50000 USD per unit
Packaging Details: Stretch film add pallet for container loading
Delivery Time: 30~35days
Payment Terms: T/T, Western Union
Supply Ability: 100 units per month
Detailed Product Description
Tube Material: Copper Fin Material: Hydrophilic Aluminum Fin Or Epoxy Resin Aluminum Fin
Frame Material: Galvanized Steel Plate Or Stainless Steel Or Aluminum Power Supply: 380V/3P/50Hz Or 380V/3P/60Hz
Fan Brand: Chinese Brand And Imported Brand Both OK Options A: Adiabatic Cooling Is OK
Options C: OEM ODM Is OK Mouting: Floor Standing
High Light:

Adiabatic dry fluid cooler

,

odm aluminum fin dry fluid cooler

,

epoxy resin aluminum fin dry cooler

Adiabatic Cooling Air Dry Coolers

 

Features

Our range of Dry Air Coolers and Radiators are designed for commercial and industrial fluid cooling applications. We offer a wide range of options enabling us to provide the most cost-effective solution for your cooling requirement.

Standard arrangements include flat-bed vertical or horizontal airflow with V configurations to offer the smallest footprint.
Whether your application is cooling water / glycol for water cooled chillers, injection moulding machines, furnace equipment, CHP Engine Cooling or any other process. One or more of our units can be selected to give the most cost-effective solution to suit your space and noise requirement.
Energy saving free cooling is possible for much of the year for many applications.

 

Application:

1. Application of dry cooler in computer room air conditioning system:

In the summer, the air conditioner operates in a normal ethylene glycol refrigeration system. When the outdoor temperature is lowered, the glycol refrigerant can be directly used for free energy saving refrigeration. At this time, the ethylene glycol circulates in the refrigeration coil, and the refrigerant circuit and the glycol loop are simultaneously cooled, thus reducing the energy consumption of the compressor.
When the outdoor temperature is much lower than the critical temperature—the single-use (energy-saving) glycol refrigeration system is enough to dissipate all the heat load in the room, the compression refrigeration system will be completely shut down, and the whole unit is equivalent to a conventional chiller with an electric valve.

D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin 0

2. Application of dry cooler in cooling production equipment system:

Summer: dry cooler cools the refrigerant through a plate exchanger or shell and tube heat exchanger.
Winter: dry cooler replaces chiller, direct cooling workshop production equipment.
D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin 1


3. Application of dry cooler in water-cooled chilled water air conditioning system:
D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin 2

4. Application of dry cooler in cold storage refrigeration system:

Summer: dry cooler cools the refrigerant through a plate exchanger or shell and tube heat exchanger.
Winter: dry cooler replaces chiller, directly supplies cooling source to the air cooler, cools the room

D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin 3

5. Application of dry cooler in cooling diesel generator set:
Cooling method: The water in the dry cooler system uses a heat exchanger to cool the circulating water or oil inside the generator.
D2 Adiabatic Dry Fluid Cooler ODM Epoxy Resin Aluminum Fin 4