Home ProductsHigh Efficiency Heat Pumps

380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller

Certification
Good quality Water Cooled Water Chiller for sales
Good quality Water Cooled Water Chiller for sales
Customer Reviews
Had a very good cooperation with you! Product use effect is good . Looking forward to cooperate with you next time !

—— Alex Welsh

I've consulted many suppliers in china for the spilt fcu and finally choose HUALI. The delivery and quality is much better than my expectation.

—— Vlado Ricardo

I've bought 20 GP Water chiller and accessories from Huali for my slaughterhouse on Aug,2015. It works well till now. Thanks for your service.

—— Tim Flavio

I'm Online Chat Now

380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller

China 380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller supplier
380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller supplier 380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller supplier

Large Image :  380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller

Product Details:

Place of Origin: DongGuan, GuangDong
Brand Name: HIGOLDEN
Certification: CE
Model Number: HLWH-110S

Payment & Shipping Terms:

Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 20 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month
Contact Now
Detailed Product Description
Name: Air Cooled Heat Pump Application: Heating-Cooling
Heating Capacity: 109-337 Kw Power Supply: 380v-50hz-3ph
Refrigerant: R22/r407c/r410a Compressor: Copeland/danfoss
Standard: CE Type: Free Standing

 

380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller

 

 

1. Specifications:

 

     Model     HLWH~

110S

160S

210S

240S

280S

310S

340S

110SH

160SH

210SH

240SH

280SH

310SH

340SH


Rated Cooling Capacity

 Cooling Capacity (KW)

109

155

208

245

283

307

337

 Comp. Input Power (KW)

34.7

47.7

63.2

71.2

82.4

89.9

99.9


Rated Heating Capacity

 Heating Capacity (KW)

119

167

224

260

301

326

360

 Comp. Input Power (KW)

32.6

44.8 

59.6 

67.0 

77.6

84.6 

94.1 

 Refrigerant 

R22

 Power Supply 

380V/ 3ph/ 50Hz

 Safety Protection


Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Water flow protection.

  Number of Refrigeration Circuit

1

 Capacity Control (%)

0, 50, 75, 100

  Refrigerant Charge (Kg)

30

42

56

68

78

84

93

 Air Cooled Heat Exchanger

  Ripple Aluminum Fins Around Copper Pipe


Water Cooled 

Heat Exchanger

  Dia.of Pipe (inch)

2-1/2"

3"

3"

3"

4"

4"

4"


Water Side Max Pressure  (MPa)

1

 Chilled  Water Flow(m3/h)

18.7

26.7

35.7

42.1

48.7

52.7

58.0

 Water Pressure Drop (kPa) 

28

33

48

55

61

64

66

 Flow of Hot Water(m3/h)

20.4

28.8

38.4

44.7

51.7

56.1

61.9


Axial Fan


Air Flow×1000m3/h

56.8

80.4

113.6

115.2

115.2

160.8

160.8

Power×Qty (KW)

1.2×4

2.0×4

1.2×8

1.2×8

1.2×8

2.0×8

2.0×8

  Running Noise dB(A)

75

75

75

75

75

75

75

  Total Weight (Kg)

1550

1960

2940

3120

3300

3480

3660

  Running Weight(Kg)

1660

2140

3160

3340

3550

3730

3980

 

 

 

 

 

 

 

 

 

 

  Heat Recovery 

  Refrigerant Charge (Kg)

35

47

54

76

85

92

101

  Heat Reclaimed Volume  (KW)

33

47

62

73

85

92

101


 Heat Recovery

 Dia.of Pipe (inch)

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2"

 
Water Side Max Pressure  (MPa)


Reclaimed  Water Flow (m3/h)

5.6

8

10.7

12.6

14.6

15.8

17.4

 Water Pressure drop (kPa) 

24

23

27

27

26

26

26

 Total Weight (Kg)

1720

2160

3180

3360

3550

3770

3980

  Running Weight(Kg)

1870

2400

3450

3680

3910

4200

4390

 

 

 

2. remark:

 

1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

Chilled water inlet/outlet temp. 12℃/7℃,  Fouling factor: 0.088㎡.°C/KW.

2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

   Hot water inlet/outlet temp. 40℃/45℃;  Hot water range: 45℃~45℃;

3. Chilled Water Range: 5~20℃;  Lowest Ambient Temperature: -5℃~43℃;

4. Heat recovery unit water in/out temperadture: 50℃/55℃;

5. Changes of Specification for lmprovement May Be made without Notice.

 

3. Application:

 

Business Organizations

supermarket, large-scale shopping malls, exclusive agency, chain shops, 

large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy.

Financial Organizations

Banks, negotiable securities, funds, insurance companies, pawnshops;

Non-profit Organizations: Telecommunications, post offices, hospital, schools;

Public Places

subway, airports, stations, gas stations, toll stations, bookstores, parks, 

exhibition halls, stadiums, museums, convention centers, ticket agencies, HR 

market, lottery centers; Real Estate Property: Apartments, villas, offices, 

commercial buildings, model rooms, property brokers;

Entertainments

Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, 

cafes, Internet bars, beauty shops, golf course

 

4. Air Cooled heat pump photos:

 

380V 50Hz R22 Screw Efficient Heat Pump High Efficiency Air Cool Chiller

Contact Details
Dongguan Golden Refrigeration Equipment Co.,Ltd

Contact Person: Miss.Aysha

Send your inquiry directly to us (0 / 3000)