Home ProductsHigh Efficiency Heat Pumps

Museum High Efficiency Heat Pumps , Double Compressor Screw Air To Air Heat Pump

Certification
Good quality Water Cooled Water Chiller for sales
Good quality Water Cooled Water Chiller for sales
Customer Reviews
Had a very good cooperation with you! Product use effect is good . Looking forward to cooperate with you next time !

—— Alex Welsh

I've consulted many suppliers in china for the spilt fcu and finally choose HUALI. The delivery and quality is much better than my expectation.

—— Vlado Ricardo

I've bought 20 GP Water chiller and accessories from Huali for my slaughterhouse on Aug,2015. It works well till now. Thanks for your service.

—— Tim Flavio

I'm Online Chat Now

Museum High Efficiency Heat Pumps , Double Compressor Screw Air To Air Heat Pump

China Museum High Efficiency Heat Pumps , Double Compressor Screw Air To Air Heat Pump supplier

Large Image :  Museum High Efficiency Heat Pumps , Double Compressor Screw Air To Air Heat Pump

Product Details:

Place of Origin: DongGuan, GuangDong
Brand Name: HIGOLDEN
Certification: CE
Model Number: HLWH-360DM

Payment & Shipping Terms:

Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 10 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month
Contact Now
Detailed Product Description
Product Name: Air Cooled Heat Pump Application: Heating-Cooling
Heating Capacity: 358-632 Kw Power Supply: 380v-50hz-3ph
Refrigeration: R22/R407C/R410A Compressor: Copeland/danfoss
Standard: CE Type: Screw Type

 

Museum High Efficiency Heat Pumps , Double Compressor Screw Air To Air Heat Pump

 

 

 

Specifications:

 

Model     HLWH~

360DM

390DM

460DM

490DM

540DM

590DM

630DM

360DHM

390DHM

460DHM

490DHM

540DHM

590DHM

630DHM

Rated Cooling

 Capacity

Cooling 

Capacity

 (KW)

358

391

464

490

536

586

632

 Comp. 

Input Power

 (KW)

116.4

127.6

141.0

148.2

164.8

180.4

197.8

Rated Heating

 Capacity

 Heating 

Capacity 

(KW)

387

423

491

518

569

622

675

 Comp. 

Input Power

 (KW)

114.4 

125.6

138.3 

145.4 

161.7 

176.9 

194.4

Refrigerant 

R407C

 Power Supply 

380V/ 3ph/ 50Hz

Safety Protection

Phase reversion protection, 

Phase lack protection, Overload 

current protection,
Discharge air temp.  protection, 

Low & High pressure protection, 

Low temp.protection, 

Water flow protection.

Number of 

Refrigeration Circuit

2

Capacity Control (%)

0, 25, 37.5, 50, 62.5, 75, 87.5, 100

 Refrigerant Charge (Kg)

114

122

146

150

164

178

196

Air Cooled 

Heat Exchanger

ipple Aluminum Fins 

Around Copper Pipe


Water Cooled 

Heat Exchanger

Dia.of Pipe

 (inch)

5"

5"

3"×2

3"×2

4"×2

4"×2

4"×2

 Water Side 

Max Pressure

  (MPa)

1

Chilled  Water

 Flow(m3/h)

61.6

67.2

79.8

84.3

92.2

100.8

108.7

Water 

Pressure 

Drop (kPa) 

42

54

44

52

54

55

65

 Flow of 

Hot Water

(m3/h)

66.6

72.7

84.4

89.1

97.9

107.0

116.1


Axial Fan

×1000m3/h 
Air Flow×

1000m3/h

172.8

172.8

230.4

230.4

230.4

321.6

321.6

Power×Qty

 (KW)

1.2×12

1.2×12

1.2×16

1.2×16

1.2×16

2.0×16

2.0×16

Running 

Noise dB(A)

75

75

75

75

75

75

75

Total Weight (Kg)

5620

5800

6240

6430

6600

6960

7320

Running Weight(Kg)

6040

6280

6680

6850

7100

7460

7960

 

 

 

 

 

 

 

 

 

 

 Heat Recovery 

 Refrigerant

 Charge (Kg)

120

128

152

156

170

184

202

 Heat Reclaimed

 Volume  (KW)

107

117

139

147

161

176

190


 Heat Recovery

Dia.of Pipe

 (inch)

2-1/2"

2-1/2"

2"×2

2"×2

2"×2

2"×2

2"×2


Water Side 

Max Pressure

  (MPa)

 
Reclaimed  

Water Flow

 (m3/h)

18.5

20.2

23.9

25.3

27.7

30.2

32.6

Water 

Pressure

 drop (kPa) 

26

26

27

27

30

30

34

Total Weight (Kg)

5170

5310

6720

6910

7100

7540

7960

 Running Weight(Kg)

5530

5840

7360

7580

7820

8400

8780

 

 

remark:

 

1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

Chilled water inlet/outlet temp. 12℃/7℃,  Fouling factor: 0.088㎡.°C/KW.

  1. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

   Hot water inlet/outlet temp. 40℃/45℃;  Hot water range: 45℃~45℃;

  1. Chilled Water Range: 5~20℃;  Lowest Ambient Temperature: -5℃~43℃;

4. Heat recovery unit water in/out temperadture: 50℃/55℃;

5. Changes of Specification for lmprovement May Be made without Notice.

 

 

3. Application:

 

Business Organizations

supermarket, large-scale shopping malls, exclusive agency, chain shops,

 large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy.

Financial Organizations

Banks, negotiable securities, funds, insurance companies, pawnshops;

Non-profit Organizations: Telecommunications, post offices, hospital, schools;

Public Places

subway, airports, stations, gas stations, toll stations, bookstores, parks, 

exhibition halls, stadiums, museums, convention centers, ticket agencies, 

HR market, lottery centers; Real Estate Property: Apartments, villas, offices, 

commercial buildings, model rooms, property brokers;

Entertainments

Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes,

 Internet bars, beauty shops, golf course

 

 

4. Water cooled chiller configuration table

 

Main accessories 

Brand

Original place

Compressor(Scroll type)

Copeland

America

Appliance Components

Schneider

French

Stainless stell tank

HUALI

Huali

Condenser

HUALI

Huali

Evaporator

HUALI

Huali

Pressure gauge

LAEADA

Guangzhou(Joint venture)

Temperature controler

PUNP

Guangzhou

Dry filter

Emerson

America

Expansion

Emerson

America

 

Contact Details
Dongguan Golden Refrigeration Equipment Co.,Ltd

Contact Person: Miss.Aysha

Send your inquiry directly to us (0 / 3000)