Home ProductsAir Cooled Water Chiller

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

Certification
Good quality Water Cooled Water Chiller for sales
Good quality Water Cooled Water Chiller for sales
Customer Reviews
Had a very good cooperation with you! Product use effect is good . Looking forward to cooperate with you next time !

—— Alex Welsh

I've consulted many suppliers in china for the spilt fcu and finally choose HUALI. The delivery and quality is much better than my expectation.

—— Vlado Ricardo

I've bought 20 GP Water chiller and accessories from Huali for my slaughterhouse on Aug,2015. It works well till now. Thanks for your service.

—— Tim Flavio

I'm Online Chat Now

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

China HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose supplier
HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose supplier HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose supplier

Large Image :  HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

Product Details:

Place of Origin: Guangdong
Brand Name: HLGOLDEN
Certification: CE
Model Number: HLWA-380D~680D

Payment & Shipping Terms:

Minimum Order Quantity: 1piece
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 20~25 Working days after received your payment
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 200 Pcs Per Month
Contact Now
Detailed Product Description
Cooling Capacity(KW): 379-675 Input Power(KW): 58.1*2-99.9*2
Power Supply: 380v-50hz-3ph Condenser: Ripple Aluminum Fins Around Copper Pipe
Certificate: CE Mount Type: Free Standing
Material: Color Plate Type: Air Cooled Water Chiller Unit

 

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

 

Chiller parameter:

 

Air Cooled Industrial Chiller
Model HLLA ~ 03SI 08SI 10SI 20DI 25DI 45TI
Rated Cooling Capacity ×1000 kcal/h 7.9 20.8 27.9 55.7 64.7 122.3
KW 9.2 24.2 32.4 64.8 75.2 142.2
Input Power (KW) 3.85 8.15 10.4 20.1 22.5 45.7
Comp. Input Power×Qty. (KW) 2.6 6.35 8.1 8.1×2 9.3×2 12.5×3
Chilled Water Pump Power (KW) 0.75 1.1 1.1 1.5 1.5 2.2
Comp. Current (A) 6.8 14 17.5 33.8 37.2 72.6
Power Supply 3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Water flow protection.
Number of Refrigeration Circuit 1 2 3
Capacity Control (%) 0, 100 0, 50, 100 0, 33, 66, 100
Refrigerant R22
Throttle device Capillary tube/Expansion valve Expansion valve
Condenser Ripple Aluminum Fins around Cooper Pipe
Power lnput of Fan (KW) 0.5 0.7 1.2 2.4 2.4 6.0
Evaporator Pipe Coil Type
Water Side Max Pressure (MPa) - 1
Dia.of Pipe to Evaporator (inch) 1" 1-1/2" 2" 2-1/2"
Chilled Water Flow (L/m) 26.4 69.4 92.9 172.0 194.8 408.3
Evaporator Water Pressure drop (kPa) - 17 23 28 28 31
Running Noise dB(A) 72 73 75 75 75 75
Tank Volume (L) 50 120 200 350 350 510
Total weight (Kg) 130 430 480 840 880 1280
Dimension L×W×H (mm) 1000×560×1000 1450×750×1200 1650×790×1300 2000×950×1650 2200×1100×1700 3300×1500×1600


Feature:
 

1. Air cooled water chiller and heat pump unit is a new generation of modular unit developed by Vicot. This

unit is energy saving and convenient in use, which has the function of reverse cycle automatic defrosting,

double steps automatic anti-freezing, built-in self-diagnosable system, and is controlled by microcomputer.

Applicable to hotels, villas, hospitals, cinemas, stadiums, recreations, office blocks, factories and so on.

 

2. It can also provide chilled water or moderate hot water for industrial purpose.

Working without water cooling tower , it provides easier installation and higher mobility . Independent cooling system .  It's a 

wonderful choice for places lacking of water or those water-cooling tower is not applicable .

Modular design : flexible combination, easily to expanding for a large cooling capacity .

 

3. Semi-hermetic screw compressor has operating steady, low noise, and less vibration features.

The unit is suitable for installing in out space such as roof, floor and porch, left off the boiler room and the

special room, decreased the investment of building project. And no need of cooling tower and cooling water

pump, this unit saves water greatly. And the unit is easy to install, manage and maintain.

 

 

Golden refrigeration equipment CO.,LTD air source heat pump series:

 

Client Customized color for you reference (our standard model is blue color)

1 . Air source water chiller ( cooling only )

2 . Air source heat pump ( cooling and heating or heating )

3 . Air source water chiller / heat pump  ( within heat recovery ) 

 

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

 

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

 

HIGOLDEN Air Cooled Water Chiller 9.2~142.2Kw Cooling Capacity For Choose

 

Our Air Cooled Water Chiller Parameter:

 

Parameter of air cooled water chiller_HUALI GROUP....