Home ProductsHorizontal Fan Coil Unit

Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow

Certification
Good quality Water Cooled Water Chiller for sales
Good quality Water Cooled Water Chiller for sales
Customer Reviews
Had a very good cooperation with you! Product use effect is good . Looking forward to cooperate with you next time !

—— Alex Welsh

I've consulted many suppliers in china for the spilt fcu and finally choose HUALI. The delivery and quality is much better than my expectation.

—— Vlado Ricardo

I've bought 20 GP Water chiller and accessories from Huali for my slaughterhouse on Aug,2015. It works well till now. Thanks for your service.

—— Tim Flavio

I'm Online Chat Now

Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow

China Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow supplier
Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow supplier Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow supplier Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow supplier Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow supplier

Large Image :  Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow

Product Details:

Place of Origin: DongGuan, GuangDong
Brand Name: HIGOLDEN
Certification: CE
Model Number: HLC-170HC

Payment & Shipping Terms:

Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton
Delivery Time: 20-24 days
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 3,000pcs per month
Contact Now
Detailed Product Description
Product Name: Horizontal Concealed Fan Coil Unit Application: Ceiling Installation
Air Flow: 170m3/h Power Supply: 220V/1PH/50HZ
Cooling Capacity: 9.6kw Heating Capacity: 14.7kw
Certification: CE Water Pipe: Copper Pipe
Noise DB(A): ≤56 Input Power: 152w
Dimension: 1680*500*260

 
Two-Pipe Ducted Horizontal Ceiling Concealed Fan Coil Unit With CE Certification
 
 
Heating Capacity : 14kw
 
1. Features 
 
HUALI Fan Coil Units provides superior whisper quiet, energy efficient performance. 
And, they are guaranteed to lower your installation and operating costs on your next new construction, 
retrofi t or  renovation project. They are available in a variety of coil configurations to offer heating,
cooling or both to a variety of spaces. Our FCUS can be installed in the ceiling (Horizontal Concealed 
and Horizontal Concealed Ultra Thin), exist as freestanding cabinet units (Vertical Exposed), mounted 
inside walls (Vertical Concealed), or furred into walls (Hi Rise).Fan Coil Units are a simple and easy 
cooling and heating solution that fits– providing reliable performance,high efficiency, ease of operation, 
low cost, easy installation, quiet comfort and a variety of customized options.
 
 
2. Application :
 
Our versatile FCUS are ideal for high-volume users like:
 
• Residential buildings
• Hotels/Motels
• Medical facilities
• Office buildings&more
• Human nature design: elegant, simple control, strong and durable, small volume, lightweight body design.
• Safe and reliable: each coil are 1.6Mpa pressure detection, the water inlet and outlet tube through forging copper structure, reliable and durable.

High efficiency and energy saving: Low energy consumption,fan and heat exchanger reasonable matching, third gear can ajust air volume, the fan power consumption is minimized.
• High efficiency: the seamless copper tube string corrugated aluminum fins, high quality of hydraulic and mechanical expansion pipe, to ensure that the combination of fin and tube, good heat transfer performance, give play to the best effect of heat transfer.

 
3. Specifications:

Model  HLC 170HC
Air flow
(m3/h)
High speed 1700
Medium speed 1275
Low speed 850
Cooling capacity High W 9657
BTU 32959
Medium W 8190
BTU 27952
Low W 6610
BTU 22560
Heating capacity High W 14732
BTU 50280
Medium W 11740
BTU 40069
Low W 8180
BTU 27918
Surplus pressure
of outlet (Pa)
Normal 0 or 12
High static pressure 30 or 50
Cooling water temperature 7-12℃
Hot water temperature 40-60℃
Power supply AC220V/50Hz
Heat Exchanger Type copper pipes covered into aluminum fins, fin pitch 2.2mm
Water supply kg/h 1602
Water resistance kPa 40
Working pressure 1.6MPa
Low static pressure FCU Input power w 152
Motor power w 25×2
High static
pressure FCU
Static pressrue
30Pa
Input power w 174
Motor power w 30×2
Static pressure
50Pa
Input power w 210
Motor power w 40×2
Fan motor quantity 4
Noise
dB(A)
Low static pressure ≤48
High static pressure 30Pa ≤50
High static pressure 50Pa ≤52
Pipe Inlet/outlet water pipe internal thread
Condensation water pipe external thread
Dimension L mm 1680
W mm 500
H mm 260
20GP container loading quantity 152
40GP container loading quantity 309


4. Photos: 
 
Two - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air FlowTwo - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air FlowTwo - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air FlowTwo - Pipe Ducted Horizontal Fan Coil Unit Ceiling Concealed 170m3/H Air Flow
 
 
 