Shanghai Shenglin M&E Technology Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPackage Heat Pump

Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger

Certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
I'm Online Chat Now

Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger

large.img.alt
small.img.alt small.img.alt

Large Image :  Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger

Product Details:

Place of Origin: China
Brand Name: Shenglin
Certification: CE
Model Number: BKFXFC series

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Packaging Details: Plywood case
Delivery Time: 18~25 days
Payment Terms: T/T, Western Union
Supply Ability: 1000 PCS/month
Detailed Product Description
Air Side Heat Exchanger Type: Finned Heat Exchanger Supply Power: 220V 1N~50Hz
Refrigerant: R22, R407C And R410A Working Ambient Temperature: -35~+43℃
Water Outlet Temp.: 45~55° C Heating Capacity: 5~11kW
Application: Ordinary Family, Villa, Office And Restaurant And Hotel, 24 Hours Apply Shower Or Washing Hands COP: 4.5
High Light:

COP4.5 Air Source Heat Pumps

,

SWEP plate Air Source Heat Pumps

,

COP4.5 inverter heat pump

DC + EVI Inverter Heating And Cooling Heat Pump

 

Description:

This series heat pump with advanced DC inverter and EVI technology, can save you 80% heating cost compare with the traditional heating device like gas/fuel boiler and electrical heater. It heats fast and works perfectly with the radiator and floor heater to provide you a comfortable living environment even in very cold winter. It is one of the best heating devices available today.


Features:

1.Twin rotary compressor with inverter control-DC inverter technology control the heat pump output according to the household`s energy requirements. Low waste of the power.
2. R410A refrigerant, environmentally friendly and no CO2 emissions.
3. Intelligentcontroller and LCD display.
4. Safelly operation with multi-protections.
5. Electronic expansion value allows the accurate refrigerant go through under different working conditions. So it ensures that the heat pump can work with high efficiency to provide enough cooling/heating capacity in any conditions.
6. Hydrophilic coating air exchanger and SWEP plate heat exchanger all available.
7. Auto defrosting function.
8. Convenient for installation and maintenance.

Optional:

Galvanized metal cabinet or stainless steel cabinet all available.
Refrigerant: R22, R407C and R410A is available
Only heating function is optional.
 

Technical paramater:

 

DC+EVI inverter heating & cooling heat pump
MODEL BKFXFC-009SMI BKFXFC-014SMI BKFXFC-018SMI
Ambient temp. range -35~+43℃ -35~+43℃ -35~+43℃
Power supply / 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz
Electric shock proof grade / Class I Class I Class I
Protection grade / IPX4 IPX4 IPX4
Rated cooling capacity A7W35 KW/- 7.5/2.81 11.5/2.82 14.5/2.82
Rated heating capacity A-12W41 KW/- 5.3/2.31 9.1/2.35 11.0/2.35
Heating capacity/COP A7W45 KW/- 8.8/3.60 14.5/3.56 17.5/3.40
A7W55 KW/- 8.1/2.74 14.2/2.92 16.8/2.70
A2W35 KW/- 7.3/3.45 12.0/3.54 14.0/3.54
A-15W45 KW/- 4.2/1.82 8.1/2.04 9.5/2.0
Compressor Type Scroll Scroll Scroll
Rated refrigerating input power/current KW/A 2.6/12.2 4.1/18.6 5.16/23.5
Rated heating input power/current. KW/A 2.30/11.1 3.87/17.6 4.68/21.2
Max. working current KW/A 4.40/20 6.6/30 7.5/34
Max. working pressure of heat exchanger Mpa 4.2 4.2 4.2
Temperature range of refrigeration outlet 5~15 5~15 5~15
Heat outlet temperature range 25~58 25~58 25~58
Water yield L/h 1300 2000 2500
Refrigerant type/Weight -/kg R410a/3.3 R410a/4.4 R410a/4.4
Noise dB/(A) ≤58 ≤59 ≤59
Dimension (W×D×H) mm 1090×435×900 1120×440×1360 1120×440×1360
Net weight kg 80 150 150
a: Rated cooling conditions: ambient temperature 35°C, inlet water temperature 12°C, outlet water temperature 7°C;
b: Rated heating conditions:environmental dry bulb temperature 7°C, wet bulb temperature 6°C, inlet water temperature 40°C, outlet water temperature 45°C;
c: Rated heating conditions:environmental dry bulb temperature -12°C, wet bulb temperature -14°C, outlet water temperature 41°C;
d: A7W45 Operating conditions: inlet air temperature 7°C, outlet air temperature 45°C.
Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard.

 

 

Reference:

 

Country: Taiwan,China, middle school
Model: KFXR-018 UII,KFXR-045UII
Application: Domestic hot water
Country: Taiwan,China,residential building
Model: KFXR-036UII,KFXR-900UII
Application: Domestic hot water
Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 0Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 1 Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 2Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 3
Country: Beijing, China
Model: KFXF-180 UII
Application: Breeding heating
Country: Yunan, China
Model: /
Application: Aloe drying
Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 4Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 5 Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 6Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 7

 

Our factory:

Hydrophilic Coating Fin Inverter Air Source Heat Pumps Cooling SWEP Plate Exchanger 8

 

Contact Details
Shanghai Shenglin M&E Technology Co., Ltd.

Contact Person: Sunny

Tel: +8613916639154

Send your inquiry directly to us (0 / 3000)