Shanghai Shenglin M&E Technology Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPackage Heat Pump

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units

Certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
I'm Online Chat Now

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units

large.img.alt
large.img.alt

Large Image :  MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units

Product Details:

Place of Origin: China
Brand Name: Shenglin
Certification: CE
Model Number: MD series

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Price: 1550~7000USD
Packaging Details: Plywood case
Delivery Time: 15~20 days
Payment Terms: T/T, Western Union
Supply Ability: 1000 PCS/month
Detailed Product Description
COP: 4 Compressor: Panasonic Or Copeland Brand
Heat Exchanger Type: One Fin Type, One Coil Type Application: House, Appartment, School, Hospital, Villa
Supply Power: 380V/3PH/50Hz Refrigerant: R22/R417A/R404A/R407C/R410A
Working Ambient Temperature: -15 ° C ~ 45 ° C Warranty: 1 Year
Installation: Freestanding Heating Capacity Range: 15~84kW
Water Outlet Temp.: 55° C
High Light:

Freestanding 84kW Air Source Heat Pumps

,

MD50D Air Source Heat Pumps

,

MD50D rooftop hvac units

Air Source Heat Pump Hot Water Type

Technical paramater:

Air source heat pump MODEL Unit MD40D
Average heating input power KW 3.78
Rated heating capacity KW 15
Hot water supply L/h 350
Rated heating input current A 9
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 55
Pipe size DN 25
Air source heat pump MODEL Unit MD50D
Average heating input power KW 4.6
Rated heating capacity KW 18.6
Hot water supply L/h 400
Rated heating input current A 9
Max outlet water temp C 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 170
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Article Parameter
Air source heat pump MODEL Unit MD60D
Average heating input power KW 5.2
Rated heating capacity KW 21
Hot water supply L/h 500
Rated heating input current A 12
Max outlet water temp 60
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 180
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000L/h
Water pressure down Kpa 48
Pipe size DN 25
Air source heat pump MODEL Unit MD100D
Average heating input power KW 9.2
Rated heating capacity KW 36
Hot water supply L/h 800
Rated heating input current A 18
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 310
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Air source heat pump MODEL Unit MD150D
Average heating input power KW 11
Rated heating capacity KW 42
Hot water supply L/h 1000
Rated heating input current A 24
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 340
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 12000L/h
Water pressure down Kpa 54
Pipe size DN 32
Article Parameter
Air source heat pump MODEL Unit MD200D
Average heating input power KW 19
Rated heating capacity KW 72
Hot water supply L/h 1600
Rated heating input current A 35
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Air source heat pump MODEL Unit MD300D
Average heating input power KW 22
Rated heating capacity KW 84
Hot water supply L/h 2000
Rated heating input current A 40
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 750
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 25000L/h
Water pressure down Kpa 60
Pipe size DN 50

 

Spare parts:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 0 Heat exchanger type A: fin heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 1 Heat exchanger type B: coil heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 2 Heat exchanger type C: plate heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 3 Electric expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 4 Expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 5 Relay
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 6 Senssor connector
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 7 Liquid, gas separator
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 8 Sensor
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 9 Thermal expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 10 Control panel

 

 

 Simple installation diagram for air source:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 11

 

Our factory:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units 12

 

Contact Details
Shanghai Shenglin M&E Technology Co., Ltd.

Contact Person: Sunny

Tel: +8613916639154

Send your inquiry directly to us (0 / 3000)