Shanghai Shenglin M&E Technology Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPackage Heat Pump

Modular Low Temperature Air Source Heat Pump Central Heating

Certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
China Shanghai Shenglin M&E Technology Co., Ltd. certification
I'm Online Chat Now

Modular Low Temperature Air Source Heat Pump Central Heating

large.img.alt
small.img.alt small.img.alt

Large Image :  Modular Low Temperature Air Source Heat Pump Central Heating

Product Details:

Place of Origin: China
Brand Name: Shenglin
Certification: CE
Model Number: HRF series

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Price: 2000~6500USD/Unit
Packaging Details: Plywood case or stretch film +pallet
Delivery Time: 30~35 days
Payment Terms: T/T, Western Union
Supply Ability: 1000 PCS/month
Detailed Product Description
Air Side Heat Exchanger Type: Finned Heat Exchanger Water Side Heat Exchanger Type: Shell Heat Exchanger
Supply Power: 380v 3N~50Hz Refrigerant: R22, R407C And R410A
Working Ambient Temperature: -22 ~ +48 ℃ Heating Capacity Range: 19.5~80kW
Max Water Outlet Temp.: 60° C Remark: Modularization
Compressor Brand: Panasonic Or Invotech Brand
High Light:

80kW packaged Air Source Heat Pump

,

HRF commercial air source heat pump

,

R407C modular scroll rooftop package units

Modular Low Temperature Air Source Heat Pump


Features:

 

1. Low temperature and high efficiency: ambient temperature -12 °C, outlet temperature 45 °C, energy efficiency ratio ≥ 2.4, ambient temperature -20 °C, outlet water temperature 45 °C energy efficiency ratio ≥ 2.0, comprehensive energy efficiency is higher than Chinese energy conservation certification;

2. Low ambient temperature and high water outlet temperature: ambient temperature -25 °C, the outlet temperature can be as high as 60 °C;

3. Stable and reliable: ambient temperature ≥ 43 °C, water outlet temperature 60 °C, ambient temperature -25 °C, water outlet temperature 60 °C, long-term stable operation;

4. Water route cleanliness: the unit water route and the water side heat transfer water route adopt the full copper design, nowhere to rust, to ensure that the water quality is not affected by the unit pipeline;

5. Advanced technology: dual electronic expansion, 3-way fin temperature sensor, optional humidity sensor to control defrosting;

6. Modularization: modular design allows for free expansion, facilitating investment in phases


Technical paramater:

 

Type   HRF20HRSPMT5 HRF36HRSPMT5 HRF42HRSPMT5 HRF80HRSPMT5
Temperature setting range 50°C (default), 25~60°C freely adjustable
Maximum input power kW 7.3 12.2 14.7 29.5
Maximum input current A 12.1 22.2 25.8 49.5
Power supply / 3N~/380V/50Hz
Refrigerant / R22
Refrigerant charge kg 3.5 6.0 6.5 2x6.5
Recirculating water pipe diameter / Rc1 internal thread Rc1-1/2 internal thread Rc1-1/2internal thread Rc1-1/2internal thread
Water side heat exchanger type / High efficiency tank heat exchanger
Water pipeline maximum pressure MPa 1.0
Length x width x height mm 1225x792x1015 1545x950x1272 1545x950x1272 2000x1060x1976
Weight kg 131 245 286 620
Noise dB(A) 63 66 66 68
Hot water working condition technical parameters
Heating capacity kW 19.5 36.0 41.6 80.0
Hot water l/h 419 774 894 1720
Input power kW 4.5 8.1 9.5 18.6
Rated water flow m3/h 3.4 6.2 7.2 13.8
Water side pressure loss kPa 32 38 45 52
Heating working condition technical parameters

Ambient temperature

(DB/WB)

Water temperature

(In/out)

   
7℃/ 6℃ 30℃/ 35℃ Heating capacity kW 16.9 30.8 35.2 69.3
Input power kW 4 7.2 8.3 16.8
40℃/ 45℃ Heating capacity kW 16.7 31.0 35.6 70
Input power kW 4.7 8.6 9.9 20.1
50℃/ 55℃ Heating capacity kW 16.5 30.8 35.2 69.2
Input power kW 5.6 10.2 11.8 23.7
55℃/ 60℃ Heating capacity kW 16.4 30.5 35 69
Input power kW 6 10.9 12.7 25.5
55℃/ 65℃ Heating capacity kW 16.4 30.7 35.1 69.1
Input power kW 6.9 12.8 14.7 29.1
-12℃/ -14℃ 36℃/ 41℃ Heating capacity kW 11 20.3 23.5 45.9
Input power kW 4.1 7.4 8.6 17.3
55℃/ 60℃ Heating capacity kW 10.5 19.7 22.8 44.8
Input power kW 5.3 9.8 11.3 22.8
Rated water flow(Δ5K/Δ10K) m3/h 2.9 / 1.5 5.4 / 2.7 6.2 / 3.1 12.0 / 6
Water side pressure loss kPa 32 38 45 52

1. Hot water test condition: dry bulb temperature 20 °C, wet bulb temperature 15 °C; initial water temperature 15 °C, end water temperature 55 °C;

2. Heating test condition 1 : dry bulb temperature 7 °C, wet bulb temperature 6 °C; inlet and outlet water temperature 30/35 °C, 40/45 °C, 55/65 °C;

3. Heating test condition 2: dry bulb temperature -12 °C, wet bulb temperature -14 °C; inlet and outlet water temperature 36/41 °C, 55/60 °C;

4. Product suitable ambient temperature range is: -22 ~ 48 °C

 

Packing:

 

Modular Low Temperature Air Source Heat Pump Central Heating 0 Modular Low Temperature Air Source Heat Pump Central Heating 1
 

 

Reference:

 

Country: Taiwan,China, middle school
Model: KFXR-018 UII,KFXR-045UII
Application: Domestic hot water
Country: Taiwan,China,residential building
Model: KFXR-036UII,KFXR-900UII
Application: Domestic hot water
Modular Low Temperature Air Source Heat Pump Central Heating 2Modular Low Temperature Air Source Heat Pump Central Heating 3 Modular Low Temperature Air Source Heat Pump Central Heating 4Modular Low Temperature Air Source Heat Pump Central Heating 5
Country: Beijing, China
Model: KFXF-180 UII
Application: Breeding heating
Country: Yunan, China
Model: /
Application: Aloe drying
Modular Low Temperature Air Source Heat Pump Central Heating 6Modular Low Temperature Air Source Heat Pump Central Heating 7 Modular Low Temperature Air Source Heat Pump Central Heating 8Modular Low Temperature Air Source Heat Pump Central Heating 9

 


 
 

Contact Details
Shanghai Shenglin M&E Technology Co., Ltd.

Contact Person: Sunny

Tel: +8613916639154

Send your inquiry directly to us (0 / 3000)